 COM20020-5
COM20020-5 ULANC
Universal Local Area Network Controller with 2K x 8 On-Board RAM
FEATURES
* * * * * * 24-Pin Embedded Network Controller/ Transceiver/RAM Ideal for Industrial/Factory Automation and Automotive Applications Deterministic, 5 Mbps, Token Passing ARCNET Protocol Minimal Microcontroller and Media Interfaces Flexible Microcontroller Interface for Use with 80XX, 68XX, etc. Automatically Detects Type of Microcontroller Interface: -Non-Multiplexed or Multiplexed Bus -Separate nRD & nWR Lines or DIR & nDS Lines Full 2Kx8 On-Chip RAM Command Chaining for Top Performance Reduced Reconfiguration Times Sequential Access to Internal RAM Software Programmable Node ID Duplicate Node ID Detection Powerful Diagnostics * * * * Receive All Mode Data Rates from 5 Mbps to 312.5 Kbps 24-Pin DIP or 28-Pin PLCC Package Flexible Media Interface: - RS485 Differential Driver Interface for Low Cost, Low Power, High Reliability - Backplane Mode for Direct Connection to Media in Short Distance Applications Eight, 256-Byte Pages Allow 4 Pages TX and RX Plus Scratch-Pad Memory No Wait-State Arbitration Programmable TXEN Polarity Next ID Readable Internal Clock Prescaler for Slower Network Speed without Slowing Arbitration o Operating Temperature Range of -40 C to o +85 C Self-Reconfiguring Protocol Supports up to 255 Nodes Supports Various Network Topologies (Star, Tree, Bus...) CMOS, Single +5V Supply
* * * * * * * * * *
* * * * * * *
GENERAL DESCRIPTION
SMSC's COM20020-5 is a member of the family of Industrial Network Controllers from Standard Microsystems Corporation. The device is a special purpose communications controller for networking microcontrollers and intelligent peripherals in industrial, automotive, and embedded control environments using an ARCNET(R) protocol engine. The small 24pin package, flexible microcontroller and media interfaces, eight-page message support, and extended temperature range of the COM20020-5 make it the only true network controller optimized for use in industrial and automotive applications. Using an ARCNET protocol engine is the ideal solution for factory automation applications because it provides a token-passing
TABLE OF CONTENTS
FEATURES ......................................................................................................................................................................... 1 GENERAL DESCRIPTION ................................................................................................................................................. 1 PIN CONFIGURATION ....................................................................................................................................................... 3 DESCRIPTION OF PIN FUNCTIONS ................................................................................................................................ 4 PROTOCOL DESCRIPTION .............................................................................................................................................. 8 NETWORK PROTOCOL ............................................................................................................................................. 8 DATA RATES ............................................................................................................................................................... 8 NETWORK RECONFIGURATION .............................................................................................................................. 8 BROADCAST MESSAGES .......................................................................................................................................... 9 EXTENDED TIMEOUT FUNCTION ............................................................................................................................. 9 LINE PROTOCOL....................................................................................................................................................... 10 SYSTEM DESCRIPTION .................................................................................................................................................. 12 MICROCONTROLLER INTERFACE ......................................................................................................................... 12 TRANSMISSION MEDIA INTERFACE ...................................................................................................................... 15 FUNCTIONAL DESCRIPTION ......................................................................................................................................... 18 MICROSEQUENCER ................................................................................................................................................. 18 INTERNAL REGISTERS ............................................................................................................................................ 18 INTERNAL RAM ......................................................................................................................................................... 30 SOFTWARE INTERFACE ......................................................................................................................................... 30 COMMAND CHAINING .............................................................................................................................................. 35 RESET DETAILS ........................................................................................................................................................ 37 INITIALIZATION SEQUENCE .................................................................................................................................... 38 IMPROVED DIAGNOSTICS ...................................................................................................................................... 38 OSCILLATOR ............................................................................................................................................................. 40 OPERATIONAL DESCRIPTION ...................................................................................................................................... 41 MAXIMUM GUARANTEED RATINGS ....................................................................................................................... 41 DC CHARACTERISTICS ........................................................................................................................................... 41 TIMING DIAGRAMS ................................................................................................................................................... 45 ERRATA SHEET............................................................................................................................................................... 57
For more details on the ARCNET protocol engine and traditional dipulse signalling schemes, please refer to the ARCNET Local Area Network Standard, available from Standard Microsystems Corporation or the ARCNET Designer's Handbook, available from Datapoint Corporation. For more detailed information on cabling options including RS485, transformer-coupled RS485 and Fiber Optic interfaces, please refer to the following technical note which is available from Standard Microsystems Corporation: Technical Note 7-5 - Cabling Guidelines for the COM20020 ULANC.
80 Arkay Drive Hauppauge, NY 11788 (516) 435-6000 FAX (516) 273-3123
2
protocol, a highly reliable and proven networking scheme, and a data rate of up to 5 Mbps when using the COM20020-5. A token-passing protocol provides predictable response times because each network event occurs within a predetermined time interval, based upon the number of nodes on the network. The deterministic nature of ARCNET is essential in mission critical applications.
The integration of the 2Kx8 RAM buffer on-chip, the Command Chaining feature, the 5 Mbps maximum data rate, and the internal diagnostics make the COM20020-5 the highest performance industrial communications device available. With only one COM20020-5 and one microcontroller, a complete communications node may be implemented.
ARCNET is a registered trademark of Datapoint Corporation
PIN CONFIGURATION
nRESET IN nPULSE2 nTXEN
21
nINTR
A0/nMUX A1 A2/ALE AD0 AD1 AD2 D3 D4 D5 D6 D7 VSS
1 2 3 4 5 6 7 8 9 10 11 12
23 22 21 20 19 18 17 16 15 14 13
nRD/nDS nWR/DIR nWR/DIR nCS nINTR nRESET IN nTXEN RXIN
nPULSE2
25 26 27 28 1 2 3 4 5
nCS
24
23
VSS
24
VDD
22
RXIN
20 19 18 17 16 15 14 13 12 nPULSE 1 XTAL2 XTAL1 VDD VSS N/C D7
nRDn/DS VDD AO/nMUX A1 A2/ALE
nPULSE1 AD0 XTAL2 XTAL1 6 7 8 9 10 11
D3
D4
D5
AD1
AD2
Packages: 24-Pin DIP or 28-Pin PLCC Ordering Information: COM20020-5 P PACKAGE TYPE: P = Plastic, LJP = PLCC TEMP RANGE: (Blank) = Commercial: 0C to +70C I = Industrial: -40C to +85C
DEVICE TYPE: 20020-5 = Universal Local Area Network Controller (with 2K x 8 RAM)
3
VSS
D6
DESCRIPTION OF PIN FUNCTIONS
DIP PIN NO. 1-3 PLCC PIN NO. 1-3 NAME SYMBOL DESCRIPTION MICROCONTROLLER INTERFACE Address A0/nMUX, Input. On a non-multiplexed bus, these 0-2 A1,A2/ALE signals are directly connected to the low bits of the host address bus. On a multiplexed address/data bus, A0/nMUX is tied low, A1 is left open, and A2 is tied to the Address Latch Enable signal of the host. A1 is connected to an internal pull-up resistor. Data 0-7 AD0-AD2, Input/Output. On a non-multiplexed bus, D3-D7 these signals are used as the data lines for the device. On a multiplexed address/data bus, AD0-AD2 act as the address lines (latched by ALE) and as the low data lines for the device. D3-D7 are always used for data only. These signals are connected to internal pull-up resistors. nRead/nDat nRD/nDS Input. On a 68XX-like bus, this active low a signal is issued by the microcontroller as the nStrobe data strobe signal to strobe the data onto the bus. On a 80XX-like bus, this active low signal is issued by the microcontroller to indicate a read operation. In this case, a logic "0" on this pin, when the COM20020-5 is accessed, enables data from the device to the data bus to be read by the microcontroller. nWrite/ nWR/DIR Input. On a 68XX-like bus, this signal is Direction issued by the microcontroller as the Read/nWrite signal to determine the direction of data transfer. In this case, a logic "1" selects a read operation, while a logic "0" selects a write operation. In this case, data is actually strobed by the nDS signal. On an 80XX-like bus, this active low signal is issued by the microcontroller to indicate a write operation. In this case, a logic "0" on this pin, when the COM20020-5 is accessed, enables data from the data bus to be written to the device.
4-11
4-6,8-12
23
27
22
26
4
DESCRIPTION OF PIN FUNCTIONS
DIP PIN NO. 19 PLCC PIN NO. NAME 23 nReset in DESCRIPTION Input. This active low signal issued by the microcontroller executes a hardware reset. It is used to activate the internal reset circuitry within the COM20020-5. nInterrupt nINTR Output. This active low signal is generated by the COM20020-5 when an enabled interrupt condition occurs. nINTR returns to its inactive state when the interrupt status condition or the corresponding interrupt mask bit is reset. nChip Select nCS Input. This active low signal issued by the microcontroller selects the COM20020-5 for an access. TRANSMISSION MEDIA INTERFACE nPulse 2, nPULSE2, Output. In Normal Mode, these active low nPulse 1 nPULSE1 signals carry the transmit data information, encoded in pulse format, from the COM20020-5 to the media driver circuitry. When the device is in Backplane Mode, the nPULSE1 signal driver is programmable (push/pull or open-drain), while the nPULSE2 signal provides a clock with frequency of crystal/4. nPULSE1 is connected to a weak internal pull-up resistor in backplane mode. Receive In RXIN Input. This signal carries the receive data information from the line receiver circuitry to the COM20020-5. nTransmit nTXEN Output. This signal is used in Backplane nEnable Mode to enable the line drivers for transmission. The polarity of the signal is programmable by grounding the nPULSE2 pin. This option is valid only in Backplane Mode. SYMBOL nRESET IN
20
24
21
25
16,15
19,18
17
20
18
21
5
MISCELLANEOUS 13,14 16,17 Crystal Oscillator XTAL1, XTAL2 An external crystal should be connected to these pins. If an external TTL clock is used instead, it must be connected to XTAL1 with a 390 pull-up resistor, and XTAL2 should be left floating. +5 Volt Power Supply pin. Ground pin.
24 12
15,28 7,14,22
Power Supply Ground
VDD VSS
6
Power On Reconfigure Timer has Timed Out Send Reconfigure Burst
Read Node ID Write ID to RAM Buffer 1 Set NID=ID
Start Reconfiguration Timer (420 mS)
Y
Invitation to Transmit to this ID?
N
N TA?
Y
Y
Free Buffer Enquiry to this ID? N
N Y Y N Write SID to Buffer DID =0? N DID =ID? N Y Write Buffer with Packet Pass the Token CRC OK? Y LENGTH OK? Y DID =0? N DID =ID? Y SEND ACK N Y Set RI N N N Y N N
Transmit NAK Transmit ACK N
Y
RI?
SOH?
RI?
Broadcast? Y Send Packet
Transmit Free Buffer Enquiry N Y ACK? Y N
No Activity for 41 uS? Y Set NID=ID Start Timer: T=(255-ID) x 73 us Activity On Line? N T=0? Y Y Broadcast Enabled? Y
N
No Activity for us? 37.35 N
Y
Was Packet Broadcast? N No Activity for us? 37.35 N N Y Y
Y
NAK? 1
Set TA
Set TA
Increment NID Set TMA
Y
ACK?
No Activity for us? 37.35
N
- ID refers to the identification number of the ID assigned to this node. - NID refers to the next identification number that receives the token after after this ID passes it. - SID refers to the source identification. - DID refers to the destination identification. - SOH refers to the start of header character; preceeds all data packets.
FIGURE 1 - COM20020-5 OPERATION
7
PROTOCOL DESCRIPTION
NETWORK PROTOCOL Communication on the network is based on a token passing protocol. Establishment of the network configuration and management of the network protocol are handled entirely by the COM20020-5's internal microcoded sequencer. A processor or intelligent peripheral transmits data by simply loading a data packet and its destination ID into the COM20020-5's internal RAM buffer, and issuing a command to enable the transmitter. When the COM20020-5 next receives the token, it verifies that the receiving node is ready by first transmitting a FREE BUFFER ENQUIRY message. If the receiving node transmits an ACKnowledge message, the data packet is transmitted followed by a 16-bit CRC. If the receiving node cannot accept the packet (typically its receiver is inhibited), it transmits a Negative AcKnowledge message and the transmitter passes the token. Once it has been established that the receiving node can accept the packet and transmission is complete, the receiving node verifies the packet. If the packet is received successfully, the receiving node transmits an ACKnowledge message (or nothing if it is not received successfully) allowing the transmitter to set the appropriate status bits to indicate successful or unsuccessful delivery of the packet. An interrupt mask permits the COM20020-5 to generate an interrupt to the processor when selected status bits become true. Figure 1 is a flow chart illustrating the internal operation of the COM20020-5 connected to a 40 MHz crystal oscillator. DATA RATES The COM20020-5 is capable of supporting data rates from 312.5 Kbps to 5 Mbps. The following protocol description assumes a 5 Mbps data rate. For slower data rates, an internal clock divider scales down the clock frequency. Thus all timeout values are scaled up as shown in the following table:
TIMEOUT SCALING FACTOR (MULTIPLY BY) 1 2 4 8 16
CLOCK PRESCALER /8 /16 /32 /64 /128
DATA RATE W/20MHz XTAL 5 Mbps 2.5 Mbps 1.25 Kbps 625 Kbps 312.5 Kbps
Example: IDLE LINE Timeout @ 5 Mbps = 41 s. IDLE LINE Timeout for 312.5 Kbps is 41 s * 16 = .66 ms NETWORK RECONFIGURATION A significant advantage of the COM20020-5 is its ability to adapt to changes on the network. Whenever a new node is activated or deactivated, a NETWORK RECONFIGURATION is performed. When a new COM20020-5 is turned on (creating a new active node on the network), or if the COM20020-5 has not received an INVITATION TO TRANSMIT for 420mS, or if a software reset occurs, the COM20020-5 causes a NETWORK RECONFIGURATION by sending a RECONFIGURE BURST consisting of eight marks and one space repeated 765 times. The purpose of this burst is to terminate all activity on the network. Since this burst is longer than any other type of transmission, the burst will interfere with the next INVITATION TO TRANSMIT, destroy the token and keep any other node from assuming control of the line.
8
When any COM20020-5 senses an idle line for greater than 41 S, which occurs only when the token is lost, each COM20020-5 starts an internal timeout equal to 73 s times the quantity 255 minus its own ID. The COM200205 starts network reconfiguration by sending an invitation to transmit first to itself and then to all other nodes by decrementing the destination Node ID. If the timeout expires with no line activity, the COM20020-5 starts sending INVITATION TO TRANSMIT with the Destination ID (DID) equal to the currently stored NID. Within a given network, only one COM20020-5 will timeout (the one with the highest ID number). After sending the INVITATION TO TRANSMIT, the COM20020-5 waits for activity on the line. If there is no activity for 37.35 S, the COM20020-5 increments the NID value and transmits another INVITATION TO TRANSMIT using the NID equal to the DID. If activity appears before the 37.35 S timeout expires, the COM20020-5 releases control of the line. During NETWORK RECONFIGURATION, INVITATIONS TO TRANSMIT are sent to all Node ID's (1 - 255). Each COM20020-5 on the network will finally have saved a NID value equal to the ID of the COM20020-5 that it released control to. At this point, control is passed directly from one node to the next with no wasted INVITATIONS TO TRANSMIT being sent to ID's not on the network, until the next NETWORK RECONFIGURATION occurs. When a node is powered off, the previous node attempts to pass the token to it by issuing an INVITATION TO TRANSMIT. Since this node does not respond, the previous node times out and transmits another INVITATION TO TRANSMIT to an incremented ID and eventually a response will be received.
The NETWORK RECONFIGURATION time depends on the number of nodes in the network, the propagation delay between nodes, and the highest ID number on the network, but is typically within the range of 12 to 30.5 ms. BROADCAST MESSAGES Broadcasting gives a particular node the ability to transmit a data packet to all nodes on the network simultaneously. ID zero is reserved for this feature and no node on the network can be assigned ID zero. To broadcast a message, the transmitting node's processor simply loads the RAM buffer with the data packet and sets the DID equal to zero. Figure 7 illustrates the position of each byte in the packet with the DID residing at address 0X01 or 1 Hex of the current page selected in the "Enable Transmit from Page fnn" command. Each individual node has the ability to ignore broadcast messages by setting the most significant bit of the "Enable Receive to Page fnn" command (see Table 5) to a logic "0". EXTENDED TIMEOUT FUNCTION There are three timeouts associated with the COM20020-5 operation. The values of these timeouts are controlled by bits 3 and 4 of the Configuration Register and bit 5 of the Setup Register. Response Time (ET1, ET2, ET3) The Response Time determines the maximum propagation delay allowed between any two nodes, and should be chosen to be larger than the round trip propagation delay between the two furthest nodes on the network plus the maximum turn around time (the time it takes a particular COM20020-5 to start sending a message in response to a received message) which is approximately 6.35 S. The round trip propagation delay is a function of the transmission media and network topology. For
9
a typical system using RG62 coax in a baseband system, a one way cable propagation delay of 15.5S translates to a distance of about 2 miles. The flow chart in Figure 1 uses a value of 37.35S (15.5 + 15.5 + 6.35) to determine if any node will respond. Idle Time (ET1, ET2, ET3) The Idle Time is associated with a NETWORK RECONFIGURATION. Figure 1 illustrates that during a NETWORK RECONFIGURATION one node will continually transmit INVITATIONS TO TRANSMIT until it encounters an active node. All other nodes on the network must distinguish between this operation and an entirely idle line. During NETWORK RECONFIGURATION, activity will appear on the line every 41S. This 41S is equal to the Response Time of 37.35S plus the time it takes the COM20020-5 to start retransmitting another message (usually another INVITATION TO TRANSMIT). Reconfiguration Time (ET1, ET2) If any node does not receive the token within the Reconfiguration Time, the node will initiate a NETWORK RECONFIGURATION. The ET2 and ET1 bits of the Configuration Register allow the network to operate over longer distances than the 2 miles stated earlier. The logic levels on these bits control the maximum distances over which the COM20020-5 can operate by controlling the three timeout values described above. For proper network operation, all COM20020-5's connected to the same network must have the same Response Time, Idle Time, and Reconfiguration Time. LINE PROTOCOL The ARCNET line protocol is considered isochronous because each byte is preceded by a start interval and ended with a stop interval. Unlike asynchronous protocols, there is a constant amount of time separating each data
byte. Each byte takes exactly 11 clock intervals that are defined by nPULSE1 and nPULSE2 signals (at 5 Mbps one byte is transmitted every 2.2S). The line idles in a spacing (logic "0") condition. A logic "0" is defined as no line activity and a logic "1" is defined as a negative pulse of 100nS duration (at 5 Mbps). A transmission starts with an ALERT BURST consisting of 6 unit intervals of mark (logic "1"). Eight bit data characters are then sent, with each character preceded by 2 unit intervals of mark and one unit interval of space. Five types of transmission can be performed as described below: Invitations To Transmit (ITT) An Invitation To Transmit is used to pass the token from one node to another and is sent by the following sequence: * An ALERT BURST * An EOT (End Of Transmission: ASCII code 04H) * Two (repeated) DID (Destination ID) characters ALERT BURST EOT DID DID
Free Buffer Enquiries (FBE) A Free Buffer Enquiry is used to ask another node if it is able to accept a packet of data. It is sent by the following sequence: * An ALERT BURST * An ENQ (ENQuiry: ASCII code 85H) * Two (repeated) DID (Destination ID) characters ALERT BURST ENQ DID DID
10
Data Packets A Data Packet consists of the actual data being sent to another node. It is sent by the following sequence: * * * * An ALERT BURST An SOH (Start Of Header--ASCII code 01H) An SID (Source ID) character Two (repeated) DID (Destination ID) characters
ALERT BURST
* A single COUNT character which is the 2's complement of the number of data bytes to follow if a short packet is sent, or 00H followed by a COUNT character if a long packet is sent * N data bytes where COUNT = 256-N (or 512N for a long packet) * Two CRC (Cyclic Redundancy Check) characters. The CRC polynomial used is: 16 15 2 X + X + X + 1.
SOH
SID
DID
DID
COUNT
data
data
CRC
CRC
Acknowledgements (ACK) An Acknowledgement is used to acknowledge reception of a packet or as an affirmative response to FREE BUFFER ENQUIRIES and is sent by the following sequence: * An ALERT BURST * An ACK (ACKnowledgement--ASCII code 86H) character ALERT BURST ACK
Negative Acknowledgements (NAK) A Negative Acknowledgement is used as a negative response to FREE BUFFER ENQUIRIES and is sent by the following sequence: * An ALERT BURST * A NAK (Negative Acknowledgement--ASCII code 15H) character ALERT BURST NAK
11
SYSTEM DESCRIPTION
MICROCONTROLLER INTERFACE Figures 2 and 3 illustrate typical COM20020-5 interfaces to the microcontrollers. The interfaces consist of an 8-bit data bus, an address bus, and a control bus. In order to support a wide range of microcontrollers without requiring glue logic and without increasing the number of pins, the COM20020-5 automatically detects and adapts to the type of microcontroller being used. Upon hardware reset, the COM20020-5 first determines whether the read and write control signals are separate READ and WRITE signals (like the 80XX) or DIRECTION and DATA STROBE (like the 68XX). To determine the type of control signals, the device requires the software to execute at least one write access to external memory before attempting to access the COM20020-5. The device defaults to 80XXlike signals. Once the type of control signals are determined, the COM20020-5 remains in this interface mode until the next hardware reset occurs. The second determination the COM20020-5 makes is whether the bus is multiplexed or nonmultiplexed. To determine the type of bus, the device requires the software to write to an odd memory location followed by a read from an odd location before attempting to access the COM20020-5. The signal on the A0 pin during the odd access tells the COM20020-5 the type of bus. Since multiplexed operation requires A0 to be active low, activity on the A0 line tells the COM20020-5 that the bus is non-multiplexed. The device defaults to multiplexed operation. Both determinations may be made simultaneously by performing a WRITE followed by a READ operation to an odd location within the COM20020-5 Address space COM20020-5 registers. Once the type of bus is determined, the COM20020-5 remains in this interface mode until hardware reset occurs. Whenever nCS and nRD are activated, the preset determinations are assumed as final and will not be changed until hardware reset. Refer to Description of Pin Functions section for details on the related signals. All accesses to the internal RAM and the internal registers are controlled by the COM20020-5. The internal RAM is accessed via a pointer-based scheme (refer to the Sequential Access Memory section), and the internal registers are accessed via direct addressing. Many peripherals are not fast enough to take advantage of high-speed microcontrollers. Since microcontrollers do not typically have READY inputs, standard peripherals cannot extend cycles to extend the access time. The access time of the COM20020-5, on the other hand, is so fast that it does not need to limit the speed of the microcontroller. The COM20020-5 is designed to be flexible so that it is independent of the microcontroller speed. The COM20020-5 provides for no wait state arbitration via direct addressing to its internal registers and a pointer based addressing scheme to access its internal RAM. Note that at the 5 Mbps data rate, the internal arbiter must be slowed down using the SLOWARB bit of the Setup Register. Although arbitration cycles are slowed down, individual cycle times will still have no wait state but the time between cycles will lengthen. The pointer may be used in autoincrement mode for typical sequential buffer emptying or loading, or it can be taken out of auto-increment mode to perform random accesses to the RAM. The data within the RAM is accessed through the data register. It is important to notice that only by writing a new address pointer (writing to address pointer low)
12
XTAL1 XTAL2 AD0-AD7 ALE A15 RESET nRD nWR nINT1
COM20020-5
AD0-AD2, D3-D7 A2/BALE nCS nRESET IN nRD/nDS nWR/DIR nINTR AO/nMUX
RXIN 75ALS176B or Equiv.
nTXEN nPULSE1 nPULSE2 GND
Differential Driver Configuration
XTAL1
XTAL2
8051
40 MHz 47 pF 1K 47 pF
* Media Interface may be replaced with Figure A, B or C.
FIGURE 2 - MULTIPLEXED, 8051-LIKE BUS INTERFACE WITH RS-485 INTERFACE
+5V
2 6 7 Receiver HFD3212-002
RXIN
+5V
RXIN
100 Ohm TXEN nPULSE1 nPULSE2 GND nPULSE1
+5V
2 6 7 Transmitter 3 HFE4211-014
2 Fiber Interface (ST Connectors) BACKPLANE CONFIGURATION
NOTE: COM20020-5 must be in Backplane Mode
FIGURE A
FIGURE B
13
XTAL1 XTAL2 D0-D7 A0 A1 A2 A7 nRES nIOS R/nW nIRQ1 D0-D7 A0/nMUX A1 A2/BALE nCS nRESET IN nRD/nDS nWR/DIR nINTR
COM20020-5
RXIN 75ALS176B or Equiv.
TXEN nPULSE1 nPULSE2 GND
Differential Driver Configuration
XTAL1
XTAL2
* Media Interface may be replaced with Figure A, B or C.
6801
40 MHz 47 pF 1K 47 pF
FIGURE 3 - NON-MULTIPLEXED, 6801-LIKE BUS INTERFACE WITH RS-485 INTERFACE
14
one obtains the contents of COM20020-5 internal RAM. Performing only read from the Data Register does not load a new data from the internal RAM. During a write operation, the data is stored in the data register and then written into memory. Whenever the pointer is loaded for reads with a new value, data is immediately prefetched to prepare for the first read operation. TRANSMISSION MEDIA INTERFACE The bottom half of Figure 2 illustrates the COM20020-5 interface to the transmission media used to connect the node to the network. The user may interface to the cable of choice in one of two ways: Backplane Configuration The Backplane Configuration is recommended for cost-sensitive, short-distance applications like backplanes and instrumentation. This mode is advantageous because it saves components, cost, and power. Since the Backplane Configuration encodes data differently than the traditional Hybrid Configuration, nodes utilizing the Backplane Configuration cannot communicate directly with nodes utilizing the Traditional Hybrid Configuration. The Backplane Configuration does not isolate the node from the media nor protects it from Common Mode noise, but Common Mode Noise is less of a problem in short distances. The COM20020-5 supplies a programmable output driver for Backplane Mode operation. A push/pull or open drain driver can be selected by programming the P1MODE bit of the Setup Register (see register descriptions for details.) The COM20020-5 defaults to an open drain output.
The Backplane Configuration provides for direct connection between the COM20020-5 and the media. Only one pull-up resistor (in open drain configuration of the output driver) is required somewhere on the media (not on each individual node). The nPULSE1 signal, in this mode, is an open drain or push/pull driver and is used to directly drive the media. It issues a 100nS negative pulse to transmit a logic "1". Note that when used in the open-drain mode, the COM20020-5 does not have a fail/safe input on the RXIN pin. The nPULSE1 signal actually contains a weak pull-up resistor. This pull-up should not take the place of the resistor required on the media for open drain mode. In typical applications, the serial backplane is terminated at both ends and a bias is provided by the external pull-up resistor. The RXIN signal is directly connected to the cable via an internal Schmitt trigger. A negative pulse on this input indicates a logic "1". Lack of pulse indicates a logic "0". For typical singleended backplane applications, RXIN is connected to nPULSE1 to make the serial backplane data line. A ground line (from the coax or twisted pair) should run in parallel with the signal. For applications requiring different treatment of the receive signal (like filtering or squelching), nPULSE1 and RXIN remain as independent pins. External differential drivers/receivers for increased range and common mode noise rejection, for example, would require the signals to be independent of one another. When the device is in Backplane Mode, the clock provided by the nPULSE2 signal may be used for encoding the data into a different encoding scheme or other synchronous operations needed on the serial data stream. Differential Driver Configuration The Differential Driver Configuration is a special case of the Backplane Mode. It is a dc coupled
15
configuration recommended for applications like car-area networks or other cost-sensitive applications which do not require direct compatibility with existing ARCNET nodes and do not require isolation. The Differential Driver Configuration cannot communicate directly with nodes utilizing the Traditional Hybrid Configuration. Like the Backplane Configuration, the Differential Driver Configuration does not isolate the node from the media. The Differential Driver interface includes a RS485 Driver/Receiver to transfer the data between the cable and the COM20020-5. The nPULSE1 signal transmits the data, provided the Transmit Enable signal is active. The nPULSE1 signal issues a 100nS negative pulse to transmit a logic "1". Lack of pulse indicates a logic "0". The RXIN signal receives the data. A negative pulse on this input indicates a logic "1". The transmitter portion of the
COM20020-5 is disabled during reset and the nPULSE1, nPULSE2 and nTXEN pins are inactive. Programmable TXEN Polarity To accommodate transceivers with active high ENABLE pins, the COM20020-5 contains a programmable TXEN output. To program the TXEN pin for an active high pulse, the nPULSE2 pin should be connected to ground. To retain the normal active low polarity, nPULSE2 should be left open. The polarity determination is made at power on reset and is valid only for Backplane Mode operation. The nPULSE2 pin should remain grounded at all times if an active high polarity is desired. Note: The COM20020-5 operates at a 5 Mbps data rate which is not compatible with previous ARCNET devices. The COM20020-5 should not be used with the HYC9088 or HYC9068 media interface hybrids.
RT
+VCC +VCC RBIAS +VCC RBIAS RBIAS
RT
75ALS176B or Equiv. COM20020-5 COM20020-5
COM20020-5
FIGURE 4 - COM20020-5 NETWORK USING RS-485 DIFFERENTIAL TRANSCEIVERS
16
A0/nMUX A1 A2/BALE
ADDRESS DECODING CIRCUITRY
2K x 8 RAM ADDITIONAL REGISTERS
AD0-AD2, D3-D7
nINTR
STATUS/ COMMAND REGISTER
nRESET IN
RESET LOGIC
MICROSEQUENCER AND WORKING REGISTERS
TX/RX LOGIC
nPULSE1 nPULSE2 nTXEN RXIN
OSCILLATOR nRD/nDS nWR/DIR nCS BUS ARBITRATION CIRCUITRY
XTAL1 XTAL2
RECONFIGURATION TIMER
NODE ID LOGIC
FIGURE 5 - INTERNAL BLOCK DIAGRAM
17
FUNCTIONAL DESCRIPTION
MICROSEQUENCER Interrupt Mask Register (IMR) The COM20020-5 contains an internal microsequencer which performs all of the control operations necessary to carry out the ARCNET protocol. It consists of a clock generator, a 544 x 8 ROM, a program counter, two instruction registers, an instruction decoder, a no-op generator, jump logic, and reconfiguration logic. The COM20020-5 derives a 10MHz and a 5MHz clock from the external crystal. These clocks provide the rate at which the instructions are executed within the COM20020-5. The 10MHz clock is the rate at which the program counter operates, while the 5MHz clock is the rate at which the instructions are executed. The microprogram is stored in the ROM and the instructions are fetched and then placed into the instruction registers. One register holds the opcode, while the other holds the immediate data. Once the instruction is fetched, it is decoded by the internal instruction decoder, at which point the COM20020-5 proceeds to execute the instruction. When a no-op instruction is encountered, the microsequencer enters a timed loop and the program counter is temporarily stopped until the loop is complete. When a jump instruction is encountered, the program counter is loaded with the jump address from the ROM. The COM20020-5 contains an internal reconfiguration timer which interrupts the microsequencer if it has timed out. At this point the program counter is cleared and the MYRECON bit of the Diagnostic Status Register is set. INTERNAL REGISTERS The COM20020-5 contains eight internal registers. Tables 1 and 2 illustrate the COM20020-5 register map. Reserved locations should not be accessed. All undefined bits are read as undefined and must be written as logic "0". The COM20020-5 is capable of generating an interrupt signal when certain status bits become true. A write to the IMR specifies which status bits will be enabled to generate an interrupt. The bit positions in the IMR are in the same position as their corresponding status bits in the Status Register and Diagnostic Status Register. A logic "1" in a particular position enables the corresponding interrupt. The Status bits capable of generating an interrupt include the Receiver Inhibited bit, New Next ID bit, Excessive NAK bit, Reconfiguration Timer bit, and Transmitter Available bit. No other Status or Diagnostic Status bits can generate an interrupt. The five maskable status bits are ANDed with their respective mask bits, and the results are ORed to produce the interrupt signal. An RI or TA interrupt is masked when the corresponding mask bit is reset to logic "0", but will reappear when the corresponding mask bit is set to logic "1" again, unless the interrupt status condition has been cleared by this time. A RECON interrupt is cleared when the "Clear Flags" command is issued. An EXCNAK interrupt is cleared when the "POR Clear Flags" command is issued. A New Next ID interrupt is cleared by reading the New Next ID Register. The Interrupt Mask Register defaults to the value 0000 0000 upon either hardware or software reset. Data Register This read/write 8-bit register is used as the channel through which the data to and from the RAM passes. The data is placed in or retrieved from the address location presently specified by the address pointer. The contents of the Data Register are undefined upon hardware reset. In case of READ operation, the Data Register is loaded with the contents of COM20020-5
18
internal RAM upon writing Address Pointer low only once. Tentative ID Register The Tentative ID Register is a read/write 8-bit register accessed when the Sub Address Bits are set up accordingly (please refer to the Configuration Register). The Tentative ID Register can be used while the node is on-line to build a network map of those nodes existing on the network. It minimizes the need for operator interaction with the network. The node determines the existence of other nodes by placing a Node ID value in the Tentative ID Register and waiting to see if the Tentative ID bit of the Diagnostic Status Register gets set. The network map developed by this method is only valid for a short period of time, since nodes may join or depart from the network at any time. When using the Tentative ID feature, a node cannot detect the existence of the next logical node to which it passes the token. The Next ID Register will hold the ID value of that node. The Tentative ID Register defaults to the value 0000 0000 upon hardware reset only. Node ID Register
placed into the Node ID Register, the core wakes up but will not join the network until the TXEN bit of the Configuration Register is set. While the Transmitter is disabled, the Receiver portion of the device is still functional and will provide the user with useful information about the network. The Node ID Register defaults to the value 0000 0000 upon hardware reset only. Next ID Register The Next ID Register is an 8-bit, read-only register, accessed when the sub-address bits are set up accordingly (please refer to the Configuration Register). The Next ID Register holds the value of the Node ID to which the COM20020-5 will pass the token. When used in conjunction with the Tentative ID Register, the Next ID Register can provide a complete network map. The Next ID Register is updated each time a node enters/leaves the network or when a network reconfiguration occurs. Each time the microsequencer updates the Next ID Register, a New Next ID interrupt is generated. This bit is cleared by reading the Next ID Register. Default value is 0000 0000 upon hardware reset. Status Register
The Node ID Register is a read/write 8-bit register accessed when the Sub Address Bits are set up accordingly (please refer to the Configuration Register). The Node ID Register contains the unique value which identifies this particular node. Each node on the network must have a unique Node ID value at all times. The Duplicate ID bit of the Diagnostic Status Register helps the user find a unique Node ID. Refer to the Initialization Sequence section for further detail on the use of the DUPID bit. The core of the COM20020-5 does not wake up until a Node ID other than zero is written into the Node ID Register. During this time, no microcode is executed, no tokens are passed by this node, and no reconfigurations are caused by this node. Once a non-zero Node ID is
The COM20020-5 Status Register is an 8-bit read-only register. All of the bits, except for bits 5 and 6, are software compatible with previous SMSC ARCNET devices. In previous SMSC ARCNET devices the Extended Timeout status was provided in bits 5 and 6 of the Status Register. In the COM20020-5, the COM90C66, and the COM90C165, COM20020, COM20051 and COM20051+, these bits exist in and are controlled by the Configuration Register. The Status Register contents are defined as in Table 3, but are defined differently during the Command Chaining operation. Please refer
19
TABLE 1 - READ REGISTER SUMMARY
READ REGISTER STATUS DIAG. STATUS ADDRESS PTR HIGH ADDRESS PTR LOW DATA MSB RI X X POR TEST RECON TMA LSB TA ADDRESS 00
MYNEW RECON DUPID RCVACT TOKEN EXCNAK TENTID NEXTID AUTOINC
X
01
RDDATA
X
X
X
A10
A9
A8
02
A7
A6
A5
A4
A3
A2
A1
A0
03
D7
D6
D5
D4
D3
D2
D1
D0
04
RESERVED
X
X
X
X
X
X
X
X
05
CONFIGURATION TENTID NODEID SETUP NEXT ID
RESET CCHEN
TXEN
ET1
ET2
BACKPLANE TID2 NID2 CKP2
SUBAD1 TID1 NID1 CKP1
SUBAD0 TID0 NID0 SLOW ARB
06
TID7 NID7 P1MODE
TID6 NID6 FOUR NAKS
TID5 NID5 ET3
TID4 NID4 RCV_ ALL
TID3 NID3 CKP3
07
NXTID7 NXTID6 NXTID5 NXTID4 NXTID3 NXTID2 NXTID1 NXTID0
Note: The SLOWARB bit of the Setup Register must be set for 5Mbps operation.
20
TABLE 2 - WRITE REGISTER SUMMARY
WRITE ADDRESS 00 MSB RI 0 0 0 EXCNAK RECON NEW NEXTID LSB TA REGISTER INTERRUPT MASK
01
D7
D6 AUTOINC
D5
D4
D3
D2
D1
D0
COMMAND ADDRESS PTR HIGH ADDRESS PTR LOW DATA
02
RDDATA
0
0
0
A10
A9
A8
03
A7
A6
A5
A4
A3
A2
A1
A0
04
D7
D6
D5
D4
D3
D2
D1
D0
05
0
0
0
0
0
0
0
0
RESERVED
06
RESET CCHEN
TXEN
ET1
ET2
BACKPLANE TID2 NID2 CKP2 0
SUBAD1 TID1 NID1 CKP1 0
SUBAD0 TID0 NID0
CONFIGURATION TENTID NODEID
TID7 NID7 07 P1MODE 0
TID6 NID6 FOUR NAKS 0
TID5 NID5 ET3 0
TID4 NID4 RCV_ ALL 0
TID3 NID3 CKP3 0
SLOW SETUP ARB 0 NEXT ID
Note: The SLOWARB bit of the Setup Register must be set for 5Mbps operation.
21
to the Command Chaining section for the definition of the Status Register during Command Chaining operation. The Status Register defaults to the value 1XX1 0001 upon either hardware or software reset. Diagnostic Status Register The Diagnostic Status Register contains seven read-only bits which help the user troubleshoot the network or node operation. Various combinations of these bits and the TXEN bit of the Configuration Register represent different situations. All of these bits, except the Excessive NAcK bit and the New Next ID bit, are reset to logic "0" upon reading the Diagnostic Status Register or upon software or hardware reset. The EXCNAK bit is reset by the "POR Clear Flags" command, upon a high level on the TA bit of the Status Register, or upon software or hardware reset. The Diagnostic Status Register defaults to the value 0000 000X upon either hardware or software reset. Command Register Execution of commands are initiated by performing microcontroller writes to this register. Any combinations of written data other than those listed in Table 5 are not permitted and may result in incorrect chip and/or network operation.
Address Pointer Registers These read/write registers are each 8-bits wide and are used for addressing the internal RAM. Writing to Low Register loads the address. The contents of the Address Pointer High and Low Registers are undefined upon hardware reset. Warning: To write a valid address to the Address Pointer Registers, one must first write to High Register and then to Low Register. Configuration Register The Configuration Register is a read/write register which is used to configure the different modes of the COM20020-5. The Configuration Register defaults to the value 0001 1000 upon hardware reset only. Setup Register The Setup Register is a read/write 8-bit register accessed when the Sub Address Bits are set up accordingly (see the bit definitions of the Configuration Register). The Setup Register allows the user to change the network speed (data rate) or the arbitration speed independently, invoke the Receive All feature, change the nPULSE1 driver type, and reduce protocol timeouts by a factor of 3. The SLOWARB bit must be set to a 1 for 5 Mbps operation. The data rate may be slowed down to 312.5 Kbps and/or the arbitration speed may be slowed down by a factor of two. The Setup Register defaults to the value 0000 0000 upon hardware reset only.
22
TABLE 3 - STATUS REGISTER
BIT
7
BIT NAME
Receiver Inhibited
SYMBOL
RI
DESCRIPTION
This bit, if high, indicates that the receiver is not enabled because either an "Enable Receive to Page fnn" command was never issued, or a packet has been deposited into the RAM buffer page fnn as specified by the last "Enable Receive to Page fnn" command. No messages will be received until this command is issued, and once the message has been received, the RI bit is set, thereby inhibiting the receiver. The RI bit is cleared by issuing an "Enable Receive to Page fnn" command. This bit, when set, will cause an interrupt if the corresponding bit of the Interrupt Mask Register (IMR) is also set. When this bit is set and another station attempts to send a packet to this station, this station will respond with a NAK. These bits are undefined.
6,5 4
(Reserved) Power On Reset POR
This bit, if high, indicates that the COM20020-5 has been reset by either a software reset, a hardware reset, or writing 00H to the Node ID Register. The POR bit is cleared by the "Clear Flags" command. This bit is intended for test and diagnostic purposes. It is a logic "0" under normal operating conditions. This bit, if high, indicates that the Line Idle Timer has timed out because the RXIN pin was idle for 41 S. The RECON bit is cleared during a "Clear Flags" command. This bit, when set, will cause an interrupt if the corresponding bit in the IMR is also set. The interrupt service routine should consist of examining the MYRECON bit of the Diagnostic Status Register to determine whether there are consecutive reconfigurations caused by this node. This bit, if high, indicates that the packet transmitted as a result of an "Enable Transmit from Page fnn" command has been acknowledged. This bit should only be considered valid after the TA bit (bit 0) is set. Broadcast messages are never acknowledged. The TMA bit is cleared by issuing the "Enable Transmit from Page fnn" command. This bit, if high, indicates that the transmitter is available for transmitting. This bit is set after the last byte of scheduled packet has been transmitted out or upon execution of a "Disable Transmitter" command. The TA bit is cleared by issuing the "Enable Transmit from Page fnn" command after the node next receives the token. This bit, when set, will cause an interrupt if the corresponding bit in the IMR is also set.
3 2
Test Reconfiguration
TEST RECON
1
Transmitter Message Acknowledged
TMA
0
Transmitter Available
TA
23
TABLE 4 - DIAGNOSTIC STATUS REGISTER
BIT
7
BIT NAME
My Reconfiguration
SYMBOL
MYRECON
DESCRIPTION
This bit, if high, indicates that a past reconfiguration was caused by this node. It is set when the Lost Token Timer times out, and should be typically read following an interrupt caused by RECON. Refer to the Improved Diagnostics section for further detail. This bit, if high, indicates that the value in the Duplicate ID Register matches both Destination ID characters of the token and a response to this token has occurred. Trailing zero's are also verified. A logic "1" on this bit indicates a duplicate Node ID, thus the user should write a new value into the Node ID Register. This bit is only useful for duplicate ID detection when the device is off line, that is, when the transmitter is disabled. When the device is on line this bit will be set every time the device gets the token. This bit is reset automatically upon reading the Diagnostic Status Register. Refer to the Improved Diagnostics section for further detail. This bit, if high, indicates that data activity (logic "1") was detected on the RXIN pin of the device. Refer to the Improved Diagnostics section for further detail. This bit, if high, indicates that a token has been seen on the network, sent by a node other than this one. Refer to the Improved Diagnostic section for further detail. This bit, if high, indicates that either 128 or 4 Negative Acknowledgements have occurred in response to the Free Buffer Enquiry. This bit is cleared upon the "POR Clear Flags" command or upon a high level on the TA bit of the Status Register. Reading the Diagnostic Status Register does not clear this bit. This bit, when set, will cause an interrupt if the corresponding bit in the IMR is also set. Refer to the Improved Diagnostics section for further detail. This bit, if high, indicates that a response to a token whose DID matches the value in the Tentative ID Register has occurred. The second DID and the trailing zero's are not checked. Since each node sees every token passed around the network, this feature can be used with the device on-line in order to build and update a network map. Refer to the Improved Diagnostics section for further detail. This bit, if high, indicates that the Next ID Register has been updated and that a node has either joined or left the network. Reading the Diagnostic Status Register does not clear this bit. This bit, when set, will cause an interrupt if the corresponding bit in the IMR is also set. The bit is cleared by reading the Next ID Register. These bits are undefined.
6
Duplicate ID
DUPID
5
Receive Activity Token Seen
RCVACT
4
TOKEN
3
Excessive NAK
EXCNAK
2
Tentative ID
TENTID
1
New Next ID
NEW NXTID
1,0
(Reserved)
24
TABLE 5 - COMMAND REGISTER
DATA
0000 0000
COMMAND
Clear Transmit Interrupt Disable Transmitter Disable Receiver
DESCRIPTION
This command is used only in the Command Chaining operation. Please refer to the Command Chaining section for definition of this command. This command will cancel any pending transmit command (transmission that has not yet started) and will set the TA (Transmitter Available) status bit to logic "1" when the COM20020-5 next receives the token. This command will cancel any pending receive command. If the COM20020-5 is not yet receiving a packet, the RI (Receiver Inhibited) bit will be set to logic "1" the next time the token is received. If packet reception is already underway, reception will run to its normal conclusion. This command allows the COM20020-5 to receive data packets into RAM buffer page fnn and resets the RI status bit to logic "0". The values placed in the "nn" bits indicate the page that the data will be received into (page 0, 1, 2, or 3). If the value of "f" is a logic "1", an offset of 256 bytes will be added to that page specified in "nn", allowing a finer resolution of the buffer. Refer to the Selecting RAM Page Size section for further detail. If the value of "b" is logic "1", the device will also receive broadcasts (transmissions to ID zero). The RI status bit is set to logic "1" upon successful reception of a message. This command prepares the COM20020-5 to begin a transmit sequence from RAM buffer page fnn the next time it receives the token. The values of the "nn" bits indicate which page to transmit from (0, 1, 2, or 3). If "f" is logic "1", an offset of 256 bytes is added to the start of the page specified in "nn", allowing a finer resolution of the buffer. Refer to the Selecting RAM Page Size section for further detail. When this command is loaded, the TA and TMA bits are reset to logic "0". The TA bit is set to logic "1" upon completion of the transmit sequence. The TMA bit will have been set by this time if the device has received an ACK from the destination node. The ACK is strictly hardware level, sent by the receiving node before its microcontroller is even aware of message reception. Refer to Figure 1 for details of the transmit sequence and its relation to the TA and TMA status bits. This command defines the maximum length of packets that may be handled by the device. If "c" is a logic "1", the device handles both long and short packets. If "c" is a logic "0", the device handles only short packets. This command resets certain status bits of the COM20020-5. A logic "1" on "p" resets the POR status bit and the EXCNAK Diagnostic status bit. A logic "1" on "r" resets the RECON status bit. This command is used only in the Command Chaining operation. Please refer to the Command Chaining section for definition of this command.
0000 0001
0000 0010
b0fn n100
Enable Receive to Page fnn
00fn n011
Enable Transmit from Page fnn
0000 c101
Define Configuration
000r p110
Clear Flags
0000 1000
Clear Receive Interrupt
25
TABLE 6 - ADDRESS POINTER HIGH REGISTER
BIT 7 BIT NAME Read Data SYMBOL RDDATA DESCRIPTION This bit tells the COM20020-5 whether the following access will be a read or write. A logic "1" prepares the device for a read, a logic "0" prepares it for a write. This bit controls whether the address pointer will increment automatically. A logic "1" on this bit allows automatic increment of the pointer after each access, while a logic "0" disables this function. Please refer to the Sequential Access Memory section for further detail. These bits are undefined. A10-A8 These bits hold the upper three address bits which provide addresses to RAM.
6
Auto Increment
AUTOINC
5-3 2-0
(reserved) Address 10-8
TABLE 7 - ADDRESS POINTER LOW REGISTER
BIT 7-0 BIT NAME Address 7-0 SYMBOL A7-A0 DESCRIPTION These bits hold the lower 8 address bits which provide the addresses to RAM. Writing to the Address Pointer Low sets the address, so the Address Pointer High should be written before Address Pointer Low.
26
TABLE 8 - CONFIGURATION REGISTER BIT
7
BIT NAME
Reset
SYMBOL
RESET
DESCRIPTION
A software reset of the COM20020-5 is executed by writing a logic "1" to this bit. A software reset does not reset the microcontroller interface mode, nor does it affect the Configuration Register. The only registers that the software reset affect are the Status Register, the Interrupt Mask Register, and the Diagnostic Status Register. This bit must be brought back to logic "0" to release the reset. This bit, if high, enables the Command Chaining operation of the device. Please refer to the Command Chaining section for further details. A low level on this bit ensures software compatibility with previous SMSC ARCNET devices. When low, this bit disables transmissions by keeping nPULSE1, nPULSE2 if in non-Backplane Mode, and nTXENABLE inactive. When high, it enables the above signals to be activated during transmissions. This bit defaults low upon reset. This bit is typically enabled once the Node ID is determined, and never disabled during normal operation. Please refer to the Improved Diagnostics section for details on evaluating network activity. These bits allow the network to operate over longer distances than the default maximum 2 miles by controlling the Response, Idle, and Reconfiguration Times. All nodes should be configured with the same timeout values for proper network operation. For the COM20020-5 with a 40 MHz crystal the bit combinations follow: ET2 0 0 1 1 ET1 0 1 0 1 Response Time ( S) 596.8 298.4 74.7 37.35 IdleTime ( S) 656 328 82 41 Reconfig Time (mS) 840 840 840 420
6
Command Chaining Enable
CCHEN
5
Transmit Enable
TXEN
4,3
Extended Timeout 1,2
ET1, ET2
2
Backplane
BACKPLANE SUBAD 1,0
A logic "1" on this bit puts the device into Backplane Mode signalling which is used for Open Drain and Differential Driver interfaces. These bits determine which register at address 07 may be accessed. The combinations are as follows: SUBAD1 0 0 1 1 SUBAD0Register 0Tentative ID 1Node ID 0Setup 1Next ID
1,0
Sub Address 1,0
27
TABLE 9- SETUP REGISTER BIT
7
BIT NAME
Pulse1 Mode
SYMBOL
P1MODE
DESCRIPTION
This bit determines the type of PULSE1 output driver used in Backplane Mode. When high, a push/pull output is used. When low, an open drain output is used. The default is open drain. This bit, when set, will cause the EXNACK bit in the Diagnostic Status Register to set after four NACKs to Free Buffer Enquiry are detected by the COM20020-5. This bit, when reset, will set the EXNACK bit after 128 NACKs to Free Buffer Enquiry. The default is 128. This bit, when set, scales down protocol timeout values of Response Time and Idle Time but NOT Reconfiguration Time to optimize network performance in short topologies. Provides a 3. Defaults to a zero. Must be reset to be scaling factor of ARCNET compliant. This bit, when set, allows the COM20020-5 to receive all valid data packets on the network, regardless of their destination ID. This mode can be used to implement a network monitor with the transmitter on- or off-line. Note that ACKs are only sent for packets received with a destination ID equal to the COM20020-5's programmed node ID. This feature can be used to put the COM20020-5 in a 'listen-only' mode, where the transmitter is disabled and the COM20020-5 is not passing tokens. Defaults low. These bits are used to determine the data rate of the COM20020-5. The following table is for a 40MHz crystal: CKP3 0 0 0 0 1 1 1 1 CKP2 0 0 1 1 0 0 1 1 CKP1 0 1 0 1 0 1 0 1 DIVISOR 8 16 32 64 128 256 SPEED 5Mbs 2.5Mbs 1.25Mbs 625Kbs 312.5Kbs Reserved Reserved Reserved
6
Four NACKS
FOUR NACKS
5
ET3
ET3
4
Receive All
RCVALL
3,2,1
Clock Prescaler Bits 3,2,1
CKP3,2,1
NOTE: The lowest data rate achievable by the COM20020-5 is 312.5Kbs. A divide by 256 is provided for those systems that use faster clock speeds. Defaults to 000 or 5Mbs. 0 Slow Arbitration Select SLW-ARB This bit, when set, will divide the arbitration clock by 2. Memory cycle times will increase when slow arbitration is selected. The SLOWARB bit must be set for 5Mbs operation. NOTE: For clock speeds greater than 20MHz, SLOWARB must be set. Defaults to low.
28
Data Register I/O Address 04H Memory Data Bus 8 2K x 8 INTERNAL RAM
D0-D7
Address Pointer Register I/O Address 02H High I/O Address 03H Low
Memory Address Bus 11-Bit Counter 11
FIGURE 6 - SEQUENTIAL ACCESS OPERATION
29
INTERNAL RAM The integration of the 2K x 8 RAM in the COM20020-5 represents significant real estate savings. The most obvious benefit is the 24-pin package in which the device is now placed (a direct result of the integration of RAM). In addition, the PC board is now free of the cumbersome external RAM, external latch, and multiplexed address/data bus and control functions which were necessary to interface to the RAM. The integration of RAM represents significant cost savings because it isolates the system designer from the changing costs of external RAM and it minimizes reliability problems, assembly time and costs, and layout complexity. Sequential Access Memory The internal RAM is accessed via a pointerbased scheme. Rather than interfering with system memory, the internal RAM is indirectly accessed through the Address High and Low Pointer Registers. The data is channeled to and from the microcontroller via the 8-bit data register. For example: a packet in the internal RAM buffer is read by the microcontroller by writing the corresponding address into the Address Pointer High and Low Registers (offsets 02H and 03H). Note that the High Register should be written first, followed by the Low Register, because writing to the Low Register loads the address. At this point the device accesses that location and places the corresponding data into the data register. The microcontroller then reads the data register (offset 04H) to obtain the data at the specified location. If the Auto Increment bit is set to logic "1", the device will automatically increment the address and place the next byte of data into the data register, again to be read by the microcontroller. This process is continued until the entire packet is read out of
RAM. Refer to Figure 6 for an illustration of the Sequential Access operation. When switching between reads and writes, the pointer must first be written with the starting address. At least one cycle time should separate the pointer being loaded and the first read (see timing parameters). Access Speed The COM20020-5 is able to accommodate very fast access cycles to its registers and buffers. Arbitration to the buffer does not slow down the cycle because the pointer based access method allows data to be prefetched from memory and stored in a temporary register. Likewise, data to be written is stored in the temporary register and then written to memory. For systems which do not require quick access time, the arbitration clock may be slowed down by setting bit 0 of the Setup Register equal to logic "1". Since the Slow Arbitration feature divides the input clock by two, the duty cycle of the input clock may be relaxed. SOFTWARE INTERFACE The microcontroller interfaces to the COM20020-5 via software by accessing the various registers. These actions are described in the Internal Registers section. The software flow for accessing the data buffer is based on the Sequential Access scheme. The basic sequence is as follows: * * * * * Disable Interrupts Write to Pointer Register High (specifying Auto-Increment mode.) Write to Pointer Register Low (this loads the address.) Enable Interrupts Read or write the Data Register (repeat as many times as necessary to empty or fill the buffer).
30
* The pointer may now be read to determine how many transfers were completed. The software flow for controlling the Configuration, Node ID, Tentative ID, and Next ID registers is generally limited to the initialization sequence and the maintenance of the network map. Additionally, it is necessary to understand the details of how the other Internal Registers are used in the transmit and receive sequences and to know how the internal RAM buffer is properly set up. The sequence of events that tie these actions together is discussed as follows. Selecting RAM Page Size During normal operation, the 2K x 8 of RAM is divided into four pages of 512 bytes each. The page to be used is specified in the "Enable Transmit (Receive) from (to) Page fnn" command, where "nn" specifies page 0, 1, 2, or 3. This allows the user to have constant control over the allocation of RAM. When the Offset bit "f" (bit 5 of the "Enable Transmit (Receive) from (to) Page fnn" command word) is set to logic "1", an offset of 256 bytes is added to the page specified. For example: to transmit from the second half of page 0, the command "Enable Transmit from Page fnn" (fnn=100 in this case) is issued by writing 0010 0011 to the Command Register. This allows a finer resolution of the buffer pages without affecting software compatibility. This scheme is useful for applications which frequently use packet sizes of 256 bytes or less, especially for microcontroller systems with limited memory capacity. The remaining portions of the buffer pages which are not allocated for current transmit or receive packets may be used as temporary storage for previous network data, packets to be sent later, or as extra memory for the system, which may be indirectly accessed.
If the device is configured to handle both long and short packets (see "Define Configuration" command), then receive pages should always be 512 bytes long because the user never knows what the length of the receive packet will be. In this case, the transmit pages may be made 256 bytes long, leaving at least 512 bytes free at any given time. Even if the Command Chaining operation is being used, 512 bytes is still guaranteed to be free because Command Chaining only requires two pages for transmit and two for receive (in this case, two 256 byte pages for transmit and two 512 byte pages for receive, leaving 512 bytes free). Please note that it is the responsibility of software to reserve 512 bytes for each receive page if the device is configured to handle long packets. The COM20020-5 does not check page boundaries during reception. If the device is configured to handle only short packets, then both transmit and receive pages may be allocated as 256 bytes long, freeing at least 1KByte at any given time. Even if the Command Chaining operation is being used, 1KByte is still guaranteed to be free because Command Chaining only requires two pages for transmit and two for receive (in this case, a total of four 256 byte pages, leaving 1K free). The general rule which may be applied to determine where in RAM a page begins is as follows: Address = (nn x 512) + (f x 256). Transmit Sequence During a transmit sequence, the microcontroller selects a 256 or 512 byte segment of the RAM buffer and writes into it. The appropriate buffer size is specified in the "Define Configuration" command. When long packets are enabled, the COM20020-5 interprets the packet as either a long or short packet, depending on whether the
31
SHORT PACKET FORMAT ADDRESS 0 1 2 SID DID COUNT = 256-N NOT USED COUNT DATA BYTE 1 DATA BYTE 2 COUNT DATA BYTE N-1 255 DATA BYTE N NOT USED 511 511 ADDRESS 0 1 2 3
LONG PACKET FORMAT SID DID 0 COUNT = 512-N NOT USED DATA BYTE 1 DATA BYTE 2
DATA BYTE N-1 DATA BYTE N
N = DATA PACKET LENGTH SID = SOURCE ID DID = DESTINATION ID (DID = 0 FOR BROADCASTS)
FIGURE 7 - RAM BUFFER PACKET CONFIGURATION
32
buffer address 2 contains a zero or non-zero value. The format of the buffer is shown in Figure 7. Address 0 contains the Source Identifier (SID); Address 1 contains the Destination Identifier (DID); Address 2 (COUNT) contains, for short packets, the value 256-N, where N represents the number of bytes (data bytes) in the message information, or for long packets, the value 0, indicating that it is indeed a long packet. In the latter case, Address 3 (COUNT) would contain the value 512-N, where N represents the number of bytes (data bytes) in the message information. The SID in Address 0 is used by the receiving node to reply to the transmitting node. The COM20020-5 puts the local ID in this location, therefore it is not necessary to write into this location. Please note that a short packet may contain between 1 and 253 data bytes, while a long packet may contain between 257 and 508 data bytes. A minimum value of 257 exists on a long packet so that the COUNT is expressable in eight bits. This leaves three exception packet lengths which do not fit into either a short or long packet; packet lengths of 254, 255, or 256 bytes. If packets of these lengths must be sent, the user must add dummy bytes to the packet in order to make the packet fit into a long packet. Once the packet is written into the buffer, the microcontroller awaits a logic "1" on the TA bit, indicating that a previous transmit command has concluded and another may be issued. Each time the message is loaded and a transmit command issued, it will take a variable amount of time before the message is transmitted, depending on the traffic on the network and the location of the token at the time the transmit command was issued. The conclusion of the Transmit Command will generate an interrupt if the Interrupt Mask allows it. If the device is configured for the Command Chaining operation, please see the Command Chaining section for further detail on the transmit sequence. Once the TA bit becomes a logic "1", the microcontroller may issue the "Enable
Transmit from Page fnn" command, which resets the TA and TMA bits to logic "0". If the message is not a BROADCAST, the COM20020-5 automatically sends a FREE BUFFER ENQUIRY to the destination node in order to send the message. At this point, one of four possibilities may occur. 1. The first possibility is if a free buffer is available at the destination node, in which case it responds with an ACKnowledgement. At this point, the COM20020-5 fetches the data from the Transmit Buffer and performs the transmit sequence. If a successful transmit sequence is completed, the TMA bit and the TA bit are set to logic "1". If the packet was not transmitted successfully, TMA will not be set. A successful transmission occurs when the receiving node responds to the packet with an ACK. An unsuccessful transmission occurs when the receiving node does not respond to the packet. 2. The second possibility is if the destination node responds to the Free Buffer Enquiry with a Negative AcKnowledgement. A NAK occurs when the RI bit of the destination node is a logic "1". In this case, the token is passed on from the transmitting node to the next node. The next time the transmitter receives the token, it will again transmit a FREE BUFFER ENQUIRY. If a NAK is again received, the token is again passed onto the next node. The Excessive NAK bit of the Diagnostic Status Register is used to prevent an endless sending of FBE's and NAK's. If no limit of FBE-NAK sequences existed, the transmitting node would continue issuing a Free Buffer Enquiry, even though it would continuously receive a NAK as a response. The EXCNAK bit generates an interrupt (if enabled) in order to tell the microcontroller to disable the transmitter via the "Disable Transmitter" command. This causes the transmission to be abandoned and the TA bit to be set to a logic "1" when the node next receives the token, while the TMA bit remains at a logic "0". Please refer to the Improved Diagnostics section for further detail on the EXCNAK bit.
33
3. The third possibility which may occur after a FREE BUFFER ENQUIRY is issued is if the destination node does not respond at all. In this case, the TA bit is set to a logic "1", while the TMA bit remains at a logic "0". The user should determine whether the node should try to reissue the transmit command. 4. The fourth possibility is if a non-traditional response is received (some pattern other than ACK or NAK, such as noise). In this case, the token is not passed onto the next node, which causes the Lost Token Timer of the next node to time out, thus generating a network reconfiguration. The "Disable Transmitter" command may be used to cancel any pending transmit command when the COM20020-5 next receives the token. Normally, in an active network, this command will set the TA status bit to a logic "1" when the token is received. If the "Disable Transmitter" command does not cause the TA bit to be set in the time it takes the token to make a round trip through the network, one of three situations exists. Either the node is disconnected from the network, or there are no other nodes on the network, or the external receive circuitry has failed. These situations can be determined by either using the improved diagnostic features of the COM20020-5 or using another software timeout which is greater than the worst case time for a round trip token pass, which occurs when all nodes transmit a maximum length message. Receive Sequence A receive sequence begins with the RI status bit becoming a logic "1", which indicates that a previous reception has concluded. The microcontroller will be interrupted if the corresponding bit in the Interrupt Mask Register is set to logic "1". Otherwise, the microcontroller must periodically check the Status Register. Once the microcontroller is
alerted to the fact that the previous reception has concluded, it may issue the "Enable Receive to Page fnn" command, which resets the RI bit to logic "0" and selects a new page in the RAM buffer. Again, the appropriate buffer size is specified in the "Define Configuration" command. Typically, the page which just received the data packet will be read by the microcontroller at this point. Once the "Enable Receive to Page fnn" command is issued, the microcontroller may attend to other duties. There is no way of knowing how long the new reception will take, since another node may transmit a packet at any time. When another node does transmit a packet to this node, and if the "Define Configuration" command has enabled the reception of long packets, the COM20020-5 interprets the packet as either a long or short packet, depending on whether the content of the buffer location 2 is zero or non-zero. The format of the buffer is shown in Figure 7. Address 0 contains the Source Identifier (SID), Address 1 contains the Destination Identifier (DID), and Address 2 contains, for short packets, the value 256-N, where N represents the number of information bytes (data bytes) in the message, or for long packets, the value 0, indicating that it is indeed a long packet. In the latter case, Address 3 contains the value 512-N, where N represents the number of information bytes (data bytes) in the message. Note that on reception, the COM20020-5 deposits packets into the RAM buffer in the same format that the transmitting node arranges them, which allows for a message to be received and then retransmitted without rearranging any bytes in the RAM buffer other than the SID and DID. Once the packet is received and stored correctly in the selected buffer and the checksum matches the packet, the COM20020-5 sets the RI bit to logic "1" to signal the microcontroller that the reception is complete.
34
MSB
LSB
TRI
RI
TA
POR
TEST
RECON
TMA
TTA
TRI
TMA
TTA
FIGURE 8 - COMMAND CHAINING STATUS REGISTER QUEUE
COMMAND CHAINING The Command Chaining operation allows consecutive transmissions and receptions to occur without host microcontroller intervention. Through the use of a dual two-level FIFO, commands to be transmitted and received, as well as the status bits, are pipelined. In order for the COM20020-5 to be compatible with previous SMSC ARCNET device drivers, the device defaults to the non-chaining mode. In order to take advantage of the Command Chaining operation, the Command Chaining Mode must be enabled via a logic "1" on bit 6 of the Configuration Register. In Command Chaining, the Status Register appears as in Figure 8. The following is a list of Command Chaining guidelines for the software programmer. Further detail can be found in the Transmit Command Chaining and Receive Command Chaining sections. * The device is designed such that the interrupt service routine latency does not affect performance. * Up to two outstanding transmissions and two outstanding receptions can be pending at any given time. The commands may be given in any order. * * Up to two outstanding transmit interrupts and two outstanding receive interrupts are stored by the device, along with their respective status bits. The Interrupt Mask bits act on TTA (Rising Transition on Transmitter Available) for transmit operations and TRI (Rising Transition of Receiver Inhibited) for receive operations. TTA is set upon completion of a packet transmission only. TRI is set upon completion of a packet reception only. Typically there is no need to mask the TTA and TRI bits after clearing the interrupt. The traditional TA and RI bits are still available to reflect the present status of the device.
*
Transmit Command Chaining When the processor issues the first "Enable Transmit to Page fnn" command, the COM20020-5 responds in the usual manner by resetting the TA and TMA bits to prepare for the transmission from the specified page. The TA bit can be used to see if there is currently a transmission pending, but the TA bit is really meant to be used in the non-chaining mode only. The TTA bits provide the relevant information for the device in the Command
35
Chaining mode. In the Command Chaining Mode, at any time after the first command is issued, the processor can issue a second "Enable Transmit from Page fnn" command. The COM20020-5 stores the fact that the second transmit command was issued, along with the page number. After the first transmission is completed, the COM20020-5 updates the Status Register by setting the TTA bit, which generates an interrupt. The interrupt service routine should read the Status Register. At this point, the TTA bit will be found to be a logic "1" and the TMA (Transmit Message Acknowledge) bit will tell the processor whether the transmission was successful. After reading the Status Register, the "Clear Transmit Interrupt" command is issued, thus resetting the TTA bit and clearing the interrupt. Note that only the "Clear Transmit Interrupt" command will clear the TTA bit and the interrupt. It is not necessary, however, to clear the bit or the interrupt right away because the status of the transmit operation is double buffered in order to retain the results of the first transmission for analysis by the processor. This information will remain in the Status Register until the "Clear Transmit Interrupt" command is issued. Note that the interrupt will remain active until the command is issued, and the second interrupt will not occur until the first interrupt is acknowledged. The COM20020-5 guarantees a minimum of 100nS interrupt inactive time interval between interrupts. The TMA bit is also double buffered to reflect whether the appropriate transmission was a success. The TMA bit should only be considered valid after the corresponding TTA bit has been set to a logic "1". The TMA bit never causes an interrupt. When the token is received again, the second transmission will be automatically initiated after the first is completed by using the stored "Enable Transmit from Page fnn" command. The operation is as if a new "Enable Transmit
from Page fnn" command has just been issued. After the first Transmit status bits are cleared, the Status Register will again be updated with the results of the second transmission and a second interrupt resulting from the second transmission will occur. The COM20020-5 guarantees a minimum of 100ns interrupt inactive time interval before the following edge. The Transmitter Available (TA) bit of the Interrupt Mask Register now masks only the TTA bit of the Status Register, not the TA bit as in the non-chaining mode. Since the TTA bit is only set upon transmission of a packet (not by RESET), and since the TTA bit may easily be reset by issuing a "Clear Transmit Interrupt" command, there is no need to use the TA bit of the Interrupt Mask Register to mask interrupts generated by the TTA bit of the Status Register. In Command Chaining mode mode, the "Disable Transmitter" command will cancel the oldest transmission. This permits canceling a packet destined for a node not ready to receive. If both packets should be canceled, two "Disable Transmitter" commands should be issued. Receive Command Chaining Like the Transmit Command Chaining operation, the processor can issue two consecutive "Enable Receive from Page fnn" commands. After the first packet is received into the first specified page, the TRI bit of the Status Register will be set to logic "1", causing an interrupt. Again, the interrupt need not be serviced immediately. Typically, the interrupt service routine will read the Status Register. At this point, the RI bit will be found to be a logic "1". After reading the Status Register, the "Clear Receive Interrupt" command should be issued, thus resetting the TRI bit and clearing the interrupt. Note that only the "Clear Receive
36
Interrupt" command will clear the TRI bit and the interrupt. It is not necessary, however, to clear the bit or the interrupt right away because the status of the receive operation is double buffered in order to retain the results of the first reception for analysis by the processor, therefore the information will remain in the Status Register until the "Clear Receive Interrupt" command is issued. Note that the interrupt will remain active until the "Clear Receive Interrupt" command is issued, and the second interrupt will be stored until the first interrupt is acknowledged. A minimum of 100nS interrupt inactive time interval between interrupts is guaranteed. The second reception will occur as soon as a second packet is sent to the node, as long as the second "Enable Receive to Page fnn" command was issued. The operation is as if a new "Enable Receive to Page fnn" command has just been issued. After the first Receive status bits are cleared, the Status Register will again be updated with the results of the second reception and a second interrupt resulting from the second reception will occur. In the COM20020-5, the Receive Inhibit (RI) bit of the Interrupt Mask Register now masks only the TRI bit of the Status Register, not the RI bit as in the non-chaining mode. Since the TRI bit is only set upon reception of a packet (not by RESET), and since the TRI bit may easily be reset by issuing a "Clear Receive Interrupt" command, there is no need to use the RI bit of the Interrupt Mask Register to mask interrupts generated by the TRI bit of the Status Register. In Command Chaining mode, the "Disable Receiver" command will cancel the oldest reception, unless the reception has already begun. If both receptions should be canceled, two "Disable Receiver" commands should be issued.
RESET DETAILS Internal Reset Logic The COM20020-5 includes special reset circuitry to guarantee smooth operation during reset. Special care is taken to assure proper operation in a variety of systems and modes of operation. The COM20020-5 contains digital filter circuitry and a Schmitt Trigger on the nRESET IN signal to reject glitches in order to ensure fault-free operation. The COM20020-5 supports two reset options; software and hardware reset. A software reset is generated when a logic "1" is written to bit 7 of the Configuration Register. The device remains in reset as long as this bit is set. The software reset does not affect the microcontroller interface modes determined after hardware reset, nor does it affect the contents of the Address Pointer Registers, the Configuration Register, or the Setup Register. A hardware reset occurs when a low signal is asserted on the nRESET IN input. The minimum reset pulse width is 1.6 s. This pulse width is used by the internal digital filter, which filters short glitches to allow only valid resets to occur. Upon reset, the transmitter portion of the device is disabled and the internal registers assume those states outlined in the Internal Registers section. After the nRESET IN signal is removed the user may write to the internal registers. Since writing a non-zero value to the Node ID Register wakes up the COM20020-5 core, the Setup
37
Register should be written before the Node ID Register. Once the Node ID Register is written to, the COM20020-5 reads the value and executes two write cycles to the RAM buffer. Address 0 is written with the data D1H and address 1 is written with the Node ID. The data pattern D1H was chosen arbitrarily, and is meant to provide assurance of proper microsequencer operation. INITIALIZATION SEQUENCE Bus Determination When the COM20020-5 is powered on the internal registers may be written to. Writing to and reading from an odd address location from the COM20020-5's address space causes the COM20020-5 to determine the appropriate bus interface. Since writing a non-zero value to the Node ID Register wakes up the core, the Setup Register should be written to before the Node ID Register. Until a non-zero value is placed into the NID Register, no microcode is executed, no tokens are passed by this node, and no reconfigurations are generated by this node. Once a non-zero value is placed in the register, the core wakes up, but the node will not attempt to join the network until the TX Enable bit of the Configuration Register is set. Before setting the TX Enable bit, the software may make some determinations. The software may first observe the Receive Activity and the Token Seen bits of the Diagnostic Status Register to verify the health of the receiver and the network. Next, the uniqueness of the Node ID value placed in the Node ID Register is determined. The TX Enable bit should still be a logic "0" until it is ensured that the Node ID is unique. If this node ID already exists, the Duplicate ID bit of the Diagnostic Status Register is set after a maximum of 420mS (or 840mS if the ET1 and ET2 bits are other than 1,1). To determine if
another node on the network already has this ID, the COM20020-5 compares the value in the Node ID Register with the DID's of the token, and determines whether there is a response to it. Once the Diagnostic Status Register is read, the DUPID bit is cleared. The user may then attempt a new ID value, wait 840mS before checking the Duplicate ID bit, and repeat the process until a unique Node ID is found. At this point, the TX Enable bit may be set to allow the node to join the network. Once the node joins the network, a reconfiguration occurs, as usual, thus setting the MYRECON bit of the Diagnostic Status Register. The Tentative ID Register may be used to build a network map of all the nodes on the network, even once the COM20020-5 has joined the network. Once a value is placed in the Tentative ID Register, the COM20020-5 looks for a response to a token whose DID matches the Tentative ID Register. The software can record this information and continue placing Tentative ID values into the register to continue building the network map. A complete network map is only valid until nodes are added to or deleted from the network. Note that a node cannot detect the existence of the next logical node on the network when using the Tentative ID. To determine the next logical node, the software should read the Next ID Register. IMPROVED DIAGNOSTICS The COM20020-5 allows the user to better manage the operation of the network through the use of the internal Diagnostic Status Register. A high level on the My Reconfiguration (MYRECON) bit indicates that the Token Reception Timer of this node expired, causing a reconfiguration by this node. After the Reconfiguration (RECON) bit of the Status Register interrupts the microcontroller, the interrupt service routine will typically read the
38
MYRECON bit of the Diagnostic Status Register. Reading the Diagnostic Status Register resets the MYRECON bit. Successive occurrences of a logic "1" on the MYRECON bit indicates that a problem exists with this node. At that point, the transmitter should be disabled so that the entire network is not held down while the node is being evaluated. The Duplicate ID (DUPID) bit is used before the node joins the network to ensure that another node with the same ID does not exist on the network. Once it is determined that the ID in the Node ID Register is unique, the software should write a logic "1" to bit 5 of the Configuration Register to enable the basic transmit function. This allows the node to join the network. The Receive Activity (RCVACT) bit of the Diagnostic Status Register will be set to a logic "1" whenever activity (logic "1") is detected on the RXIN pin. The Token Seen (TOKEN) bit is set to a logic "1" whenever any token has been seen on the network (except those tokens transmitted by this node). The RCVACT and TOKEN bits may help the user to troubleshoot the network or the node. If unusual events are occurring on the network, the user may find it valuable to use the TXEN bit of the Configuration Register to qualify events. Different combinations of the RCVACT, TOKEN, and TXEN bits, as shown indicate different situations: Normal Results: RCVACT=1, TOKEN=1, TXEN=0: The node is not part of the network. The network is operating properly without this node. RCVACT=1, TOKEN=1, TXEN=1: The node sees receive activity and sees the token. The basic transmit function is enabled. Network and node are operating properly.
MYRECON=0, DUPID=0, RCVACT=1, TXEN=0, TOKEN=1: Single node network. Abnormal Results: RCVACT=1, TOKEN=0, TXEN=X: The node sees receive activity, but does not see the token. Either no other nodes exist on the network, some type of data corruption exists, the media driver is malfunctioning, the topology is set up incorrectly, there is noise on the network, or a reconfiguration is occurring. RCVACT=0, TOKEN=0, TXEN=1: No receive activity is seen and the basic transmit function is enabled. The transmitter and/or receiver are not functioning properly. RCVACT=0, TOKEN=0, TXEN=0: No receive activity and basic transmit function disabled. This node is not connected to the network. The Excessive NAK (EXCNAK) bit is used to replace a timeout function traditionally implemented in software. This function is necessary to limit the number of times a sender issues a FBE to a node with no available buffer. When the destination node replies to 128 FBEs with 128 NAKs or 4 FBEs with 4 NAKs, the EXCNAK bit of the sender is set, generating an interrupt. At this point the software may abandon the transmission via the "Disable Transmitter" command. This sets the TA bit to logic "1" when the node next receives the token, to allow a different transmission to occur. The timeout value for the EXNACK bit (128 or 4) is determined by the FOUR-NAKS bit on the Setup Register. The user may choose to wait for more NAK's before disabling the transmitter by taking advantage of the wraparound counter of the EXCNAK bit. When the EXCNAK bit goes high, indicating 128 or 4 NAKs, the "POR Clear Flags" command may be issued to reset the bit so that it will go high again after another count
39
of 128 or 4. The software may count the number of times the EXCNAK bit goes high, and once the final count is reached, the "Disable Transmitter" command may be issued. The New Next ID bit permits the software to detect the withdrawal or addition of nodes to the network. The Tentative ID bit allows the user to build a network map of those nodes existing on the network. This feature is useful because it minimizes the need for human intervention. When a value placed in the Tentative ID Register matches the Node ID of another node on the network, the TENTID bit is set, telling the software that this NODE ID already exists on the network. The software should periodically place values in the Tentative ID Register and monitor the New Next ID bit to maintain an updated network map.
OSCILLATOR The COM20020-5 contains circuitry which, in conjunction with an external parallel resonant crystal or TTL clock, forms an oscillator. If an external crystal is used, two capacitors and one resistor are needed (one from each leg of the crystal to ground). A 1K resistor is required, and the crystal must have an accuracy of 0.020% or better. The XTAL2 side of the crystal may be loaded with a single 74HC-type buffer in order to generate a clock for other devices. The user may attach an external TTL clock, rather than a crystal, to the XTAL1 signal. In this case, a 390 pull-up resistor is required on XTAL1, while XTAL2 should be left unconnected.
Third Overtone such as Ecliptek EC400-40.0000 XTAL1 40 MHz 1k XTAL2
COM20020-5
47pF 47pF
FIGURE 9 - OSCILLATOR CIRCUIT
40
OPERATIONAL DESCRIPTION
MAXIMUM GUARANTEED RATINGS* Operating Temperature Range........................................................................................ 0 C to +70 C o o Storage Temperature Range ...................................................................................... -55 C to +150 C o Lead Temperature (soldering, 10 seconds) .............................................................................. +325 C Positive Voltage on any pin, with respect to ground ............................................................... VDD+0.3V Negative Voltage on any pin, with respect to ground .................................................................... -0.3V Maximum VDD ............................................................................................................................... +7V *Stresses above those listed may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other condition above those indicated in the operational sections of this specification is not implied. NOTE: When powering this device from laboratory or system power supplies, it is important that the Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit voltage spikes or "glitches" on their outputs when the AC power is switched on or off. In addition, voltage transients on the AC power line may appear on the DC output. If this possibility exists it is suggested that a clamp circuit be used. DC ELECTRICAL CHARACTERISTICS VDD=5.0V 10% o o COM20020-5I: TA=-40 C to +85 C PARAMETER SYMBOL MIN TYP Low Input Voltage 1 (All inputs except A2, XTAL1, nRESET, nRD, nWR, and RXIN) High Input Voltage 1 (All inputs except A2, XTAL1, nRESET, nRD, nWR, and RXIN) Low Input Voltage 2 (XTAL1) High Input Voltage 2 (XTAL1) Low to High Threshold Input Voltage (A2, nRESET, nRD, nWR, RXIN) High to Low Threshold Input Voltage (A2, nRESET, nRD, nWR, RXIN) VIL1
o o
MAX 0.8
UNIT V
COMMENT TTL Levels
VIH1
2.0
V
TTL Levels
VIL2 VIH2 VILH 4.0 1.8
1.0
V V V
TTL Clock Input
Schmitt Trigger, All Values at VDD = 5V
VIHL
1.2
V
41
PARAMETER Low Output Voltage 1 (nPULSE in Normal Mode, nPULSE2, nTXEN) High Output Voltage 1 (nPULSE1 in Normal Mode, nPULSE2, nTXEN) Low Output Voltage 2 (D0-D7) High Output Voltage 2 (D0-D7) Low Output Voltage 3 (nINTR) High Output Voltage 3 (nINTR) Low Output Voltage 4 (nPULSE1 in Backplane Mode - Open Drain) Dynamic VDD Supply Current 1 Input Pull-up Current (nPULSE1 in Backplane Mode, A1, AD0-AD2, D3-D7) Input Leakage Current (All inputs except A1, AD0-AD2, D3-D7, XTAL1, XTAL2)
SYMBOL VOL1
MIN
TYP
MAX 0.4
UNIT V
COMMENT ISINK=4mA
VOH1
2.4
V
ISOURCE=-2mA
VOL2 VOH2 VOL3 VOH3 VOL4 2.4 2.4
0.4
V V
ISINK=16mA ISOURCE=-12mA ISINK=24mA ISOURCE=-10mA ISINK=48mA Open Drain Driver
0.8
V V
0.5
V
IDD1 IP 80
60 200
mA A VIN=0.0V
IL
10
A
VSS < VIN < VDD
42
CAPACITANCE (TA = 25 C; fC = 1MHz; VDD = 0V) Output and I/O pins capacitive load specified as follows: PARAMETER SYMBOL MIN TYP Input Capacitance Output Capacitance 1 (All outputs except nPULSE1 in BackPlane Mode) Output Capacitance 2 (nPULSE1, in BackPlane Mode Only - Open Drain) CIN COUT1
MAX 5.0 45
UNIT pF pF
COMMENT Maximum Capacitive Load which can be supported by each output.
COUT2
400
pF
AC Measurements are taken at the following points: Inputs: t t 2.4V 1.4V 0.4V t 2.4V 1.4V 0.4V 50% 0.8V t 2.0V 50% 0.8V 2.0V Outputs:
Inputs are driven at 2.4V for logic "1" and 0.4 V for logic "0". Outputs are measured at 2.0V min. for logic "1" and 0.8V max. for logic "0".
43
AD0-AD2, D3-D7 VALID t1 nCS t3 ALE nDS t5 t8 DIR t9 t10 t6 t2, t4 VALID DATA
t7
Parameter t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 Address Setup to ALE Low Address Hold from ALE Low nCS Setup to ALE Low nCS Hold from ALE Low ALE Low to nDS Low nDS Low to Valid Data nDS High to Data High Impedance Cycle Time (nDS Low to Next Time Low) DIR Setup to nDS Active DIR Hold from nDS Inactive
min 30 10 10 20 15 0 4T* 10 10
max
units nS nS nS nS nS nS nS nS nS nS
40 20
* T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles.
FIGURE 10 - MULTIPLEXED BUS, 68XX-LIKE CONTROL SIGNALS; READ CYCLE
44
AD0-AD2, D3-D7 VALID t1 nCS t3 ALE nRD t5 t8 t6 t2, t4 VALID DATA
t7
Parameter t1 t2 t3 t4 t5 t6 t7 t8 Address Setup to ALE Low Address Hold from ALE Low nCS Setup to ALE Low nCS Hold from ALE Low ALE Low to nRD Low nRD Low to Valid Data nRD High to Data High Impedance Cycle Time (nRD Low to Next Time Low)
min 30 10 10 20 15 0 4T*
max
units nS nS nS nS nS nS nS nS
40 20
* T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles.
FIGURE 10A - MULTIPLEXED BUS, 80XX-LIKE CONTROL SIGNALS; READ CYCLE
45
AD0-AD2, D3-D7 t1 nCS
VALID t2, t4 t3
VALID DATA
ALE t5 nDS t7 t6 Note 2 t8** t8 DIR t9 Parameter t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 Address Setup to ALE Low Address Hold from ALE Low nCS Setup to ALE Low nCS Hold from ALE Low ALE Low to nDS Low Valid Data Setup to nDS High Data Hold from nDS High Cycle Time (nDS Low to Next Time Low)** DIR Setup to nDS Active DIR Hold from nDS Inactive min 30 10 10 20 15 30 10 4T* 10 10 max t10 units nS nS nS nS nS nS nS nS nS nS
* T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles.
** Note 2: Any cycle occurring after a write to Address Pointer Low Register requires a minimum of 4T from the trailing edge of nDS to the leading edge of the next nDS.
FIGURE 11 - MULTIPLEXED BUS, 68XX-LIKE CONTROL SIGNALS; WRITE CYCLE
46
AD0-AD2, D3-D7 t1 nCS
VALID t2, t4 t3
VALID DATA
ALE t5 nWR t7 t6 Note 2 t8** t8
Parameter t1 t2 t3 t4 t5 t6 t7 t8 Address Setup to ALE Low Address Hold from ALE Low nCS Setup to ALE Low nCS Hold from ALE Low ALE Low to nWR Low Valid Data Setup to nWR High Data Hold from nWR High Cycle Time (nWR Low to Next Time Low)**
min 30 10 10 20 15 30 10 4T*
max
units nS nS nS nS nS nS nS nS
* T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles.
** Note 2: Any cycle occurring after a write to Address Pointer Low Register requires a minimum of 4T from the trailing edge of nWR to the leading edge of the next nWR.
FIGURE 11A - MULTIPLEXED BUS, 80XX-LIKE CONTROL SIGNALS; WRITE CYCLE
47
A0-A2 t1 nCS
VALID t2
t4 t3 t5 nRD t6 D0-D7 VALID DATA t7
Parameter t1 t2 t3 t4 t5 t6 t7 * Address Setup to nRD Active Address Hold from nRD Inactive nCS Setup to nRD Active nCS Hold from nRD Inactive Cycle Time (nRD Low to Next Time Low) nRD Low to Valid Data nRD High to Data High Impedance
min 15 10 5** 0 4T* 0
max
units nS nS nS nS nS nS nS
40 20
**
T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 nCS may become active after control becomes active, but the access time will now be 45nS measured from the leading edge of nCS.
Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles.
FIGURE 12 - NON-MULTIPLEXED BUS, 80XX-LIKE CONTROL SIGNALS; READ CYCLE
48
A0-A2 t1 nCS t3 DIR nDS t8 D0-D7 Parameter t1 t2 t3 t4 t5 t6 t7 t8 t9 * t5
VALID t2
t4 t7 t6
t9 VALID DATA min 15 10 5** 0 10 4T* 10 0 40 20 max units nS nS nS nS nS nS nS nS nS
Address Setup to nDS Active Address Hold from nDS Inactive nCS Setup to nDS Active nCS Hold from nDS Inactive DIR Setup to nDS Active Cycle Time (nDS Low to Next Time Low) nDIR Hold from nDS Active nDS Low to Valid Data nDS High to Data High Impedence
T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1
**
nCS may become active after control becomes active, but the access time will now be 45nS measured from the leading edge of nCS. Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles.
FIGURE 12A - NON-MULTIPLEXED BUS, 68XX-LIKE CONTROL SIGNALS; READ CYCLE
49
A0-A2 t1 nCS
VALID t2
t4 t3 t5 t6 D0-D7 VALID DATA Parameter Address Setup to nWR Active Address Hold from nWR Inactive nCS Setup to nWR Active nCS Hold from nWR Inactive Cycle Time (nWR Low to Next Time Low)** Valid Data Setup to nWR High Data Hold from nWR High min 15 10 5 0 4T* 30** 10 max units nS nS nS nS nS nS nS Note 2 t5** t7
nWR
t1 t2 t3 t4 t5 t6 t7
* T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 **nCS may become active after control becomes active, but the data setup time will now be 30 nS measured from the later of nCS falling or Valid Data available. Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles. Note 2: Any cycle occurring after a write to the Address Pointer Low Register requires a minimum of 4T from the trailing edge of nWR to the leading edge of the next nWR.
FIGURE 13 - NON-MULTIPLEXED BUS, 80XX-LIKE CONTROL SIGNALS; WRITE CYCLE
50
A0-A2 t1 nCS
VALID t2
t4 DIR t3 t5 nDS t6 t8 D0-D7 VALID DATA Parameter Address Setup to nDS Active Address Hold from nDS Inactive nCS Setup to nDS Active nCS Hold from nDS Inactive DIR Setup to nDS Active Cycle Time (nDS Low to Next Time Low)** DIR Hold from nDS Inactive Valid Data Setup to nDS High Data Hold from nDS High min 15 10 5 0 10 4T* 10 30** 10 max units nS nS nS nS nS nS nS nS nS t7 Note 2 t6** t9
t1 t2 t3 t4 t5 t6 t7 t8 t9
* T is the Arbitration Clock Period. T is identical to XTAL1 if SLOW ARB = 0, T is twice XTAL1 period if SLOW ARB = 1 **nCS may become active after control becomes active, but the data setup time will now be 30 nS measured from the later of nCS falling or Valid Data available. Note 1: The Microcontroller typically accesses the COM20020-5 on every other cycle. Therefore, the cycle time specified in the microcontroller's datasheet should be doubled when considering back-to-back COM20020-5 cycles. Note 2: Any cycle occurring after a write to the Address Pointer Low Register requires a minimum of 4T from the trailing edge of nDS to the leading edge of the next nDS.
FIGURE 13A - NON-MULTIPLEXED BUS, 68XX-LIKE CONTROL SIGNALS; WRITE CYCLE
51
nTXEN t4 t2 t1 nPULSE1 LAST BIT (200 nS BIT TIME) t2 t1 nPULSE2 t5
t3
t6 RXIN t7 Parameter t1 t2 t3 t4 t5 t6 t7 nPULSE1, nPULSE2 Pulse Width nPULSE1, nPULSE2 Period nPULSE1, nPULSE2 Overlap nTXEN Low to nPULSE1 Low** Beginning of Last Bit Time to nTXEN High** RXIN Pulse Width RXIN Period min typ 50 * 200 * 0 50 * 200 * max units nS nS nS nS nS nS nS
-10 400 100 10
+10 500 200
* t1 = 2 x (crystal period) for clock frequencies other than 40 MHz. * t2,t7 = 8 x (crystal period) for clock frequencies other than 40 MHz. This period applies to data of two consecutive one's. ** t4: For clock frequencies other than 40 MHz, t4 = 18 x (crystal period) 50 nsec. ** t5: For clock frequencies other than 40 MHz, t5 = 6 x (crystal period) 50 nsec.
FIGURE 14 - NORMAL MODE TRANSMIT OR RECEIVE TIMING
52
nTXEN t1 t3 nPULSE1 t9 t4 nPULSE2 (Internal Clk) t5 t7 t6 t2 LAST BIT (200 nS BIT TIME) t8
t10 RXIN t11 Parameter t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 nPULSE2 High to nTXEN Low nPULSE1 Pulse Width nPULSE1 Period nPULSE2 Low to nPULSE1 Low nPULSE2 High Time nPULSE2 Low Time nPULSE2 Period nPULSE2 High to nTXEN High (First rising edge on nPULSE2 after Last Bit Time) nTXEN Low to first nPULSE1 Low**
min 0
typ 100* 200*
max 25
units nS nS nS nS nS nS nS nS nS nS nS
0 50* 50* 100* 0 300
25
25 400
10 100* RXIN Pulse Width RXIN Period 200* * t5,t6 = 2 x (crystal period) for clock frequencies other than 40 MHz. * t2,t7,t10 = 4 x (crystal period) for clock frequencies other than 40 MHz. * t3,t11 = 8 x (crystal period) for clock frequencies other than 40 MHz. This period applies to data of two consecutive one's. ** t9: For clock frequencies other than 40 MHz, t9 = 14 x (clock period) 50 nsec.
FIGURE 15 - BACKPLANE MODE TRANSMIT OR RECEIVE TIMING
(These signals are to and from the differential driver or the cable)
53
t1 XTAL1 Parameter t1 t2 t3 t4 Input Clock High Time Input Clock Low Time Input Clock Period Input Clock Frequency
t2
t3
min 10 10 25 10
typ
max
units nS nS nS MHz
100 40
FIGURE 16 - TTL INPUT TIMING ON XTAL1 PIN
t1 nRESET IN
nINTR Parameter t1 t2 nRESET IN Pulse Width nINTR High to Next nINTR Low
t2 min 1.6 200 typ max units S nS
FIGURE 17 - RESET AND INTERRUPT TIMING
54
G E
PIN NO. 1
J F
A
B B1 D3 D2
R
J D1 D
J A1
C
DIM A A1 B B1 C D D1 D2 D3 E F G J R NOTES:
28L .160-.180 .090-.120 .013-.021 .026-.032 .020-.045 .485-.495 .450-.456 .390-.430 .300 REF .050 BSC .042-.056 .042-.048 .000-.020 .025-.045
1. All dimensions are in inches. 2. Circle indicating pin 1 can appear on a top surface as shown on the drawing or right above it on a beveled edge.
FIGURE 18 - 28-PIN PLCC PACKAGE DIMENSIONS
55
Seating Plane
Base Plane
E1 E
C eA D eB A2
Base Plane
A
A1 Seating Plane B1 S e B L
DIM A A1 A2 B B1 C D E E1 e eA eB L S Note: All dimensions are in inches.
24L .090-.200 .020-.065 .145-.155 .016-.021 .060-.070 .010-.014 1.245-1.265 .590-.630 .530-.545 .100BSC .600REF .610-.670 .120-.140 .065-.085
FIGURE 18A - 24-PIN DIP PACKAGE DIMENSIONS
56
COM20020-5 ERRATA SHEET
PAGE 8 9 9 9 10 10 10 10 10 11 11 12 15 16 19 19 22 22 23 26 27 28 33 34 38 42 SECTION/FIGURE/ENTRY Network Protocol Network Reconfiguration Extended Timeout Function Response Time Idle Time Reconfiguration Time Line Protocol Invitations to Transmit Free Buffer Enquiries Acknowledgements Negative Acknowledgements Microcontroller Interface Backplane Configuration Programmable TXEN Polarity Data Register Status Register Address Pointer Registers Configuration Registers Bit 7, Bit 0 Bit 7 - 0 Bit 4,3 Bit 5, Bit 3,2,1 Transmit Sequence Receive Sequence Initialization Sequence Comment CORRECTION See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text See Italicized Text DATE REVISED 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95 04/14/95
57
1995(c) STANDARD MICROSYSTEMS CORP.
Circuit diagrams utilizing SMSC products are included as a means of illustrating typical applications; consequently complete information sufficient for construction purposes is not necessarily given. The information has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies. Furthermore, such information does not convey to the purchaser of the semiconductor devices described any licenses under the patent rights of SMSC or others. SMSC reserves the right to make changes at any time in order to improve design and supply the best product possible. SMSC products are not designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. COM20020-5 Rev. 4/14/95


▲Up To Search▲   

 
Price & Availability of COM20020-5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X